ADD-200

Wireless outdoor dusk and temperature detector

ADD-200 detects changes of light intensity (dusk detector) and temperature (temperature detector). It is designed to work within the ABAX 2 two-way wireless system. The detector is supported by the ACU-220 and ACU-280 controllers and the ARU-200 radio signal repeater.

  • dusk detector:
    • light intensity measurement in the range of 2 lx and 250 lx
    • option to select one of 16 detection thresholds
    • immunity to short and accidental changes of light intensity
  • temperature detector:
    • temperature measurement in the range of -30°C and +70°C
    • programmable temperature threshold
  • encrypted two-way radio communication in the 868 MHz (AES standard)
  • transmission channel diversity – automatic selection of the one of 4 channels that will enable transmission without interference with other signals in the 868 MHz frequency band
  • radio communication range in open area: up to 2000 m (with ACU-220) / up to 1600 m (with ACU-280)
  • remote update of detector firmware
  • remote configuration
  • LED indicator
  • “ECO” option for longer battery life
  • battery status control
  • weatherproof enclosure of high mechanical strength
ADD-200
The actual appearance of the products may differ from the presented images. Product descriptions are provided in the web service for information purposes only.

Documentation

general information manual
updated: 2024-07-09
216 KB
quick installer guide
updated: 2024-06-04
405 KB

Certificates

EU declaration of conformity
updated: 2024-07-17
115 KB

Technical Data

Battery working time (in years)
up to 2
Operating temperature range
-20°C...+55°C
Max. current consumption
12 mA
Weight
95 g
Maximum humidity
93±3%
Operating frequency band
868,0 ÷ 868,6 MHz
Battery
CR123A 3V
Standby current consumption
20 µA
Dimensions
58 x 115 x 34 mm
Environmental class according to EN50130-5
III
Temperature measurement accuracy
±1°C
Warm-up period
5 s
IP code
IP65
Radio communication range (in open area) for ACU-220
up to 2000 m
Radio communication range (in open area) for ACU-280
up to 1600 m
Temperature measurement range
-20°C...+55°C
Light intensity measurement in range
2...250 lx

Information materials

1catalogue

2leaflet - end user

3leaflet - installer

4technical data

5product data sheet