ASW-210
Wireless two-channel 230 V AC in-wall controller
The ASW-210 module is designed to remotely switch on/off devices powered from 230 V AC mains. It operates as part of the ABAX 2/ABAX two-way wireless system.
The controller has compact dimensions and is designed for in-wall mounting.
The device is provided with two control inputs designed to connect e.g. wall switches (mono- and bistable).
Configuration and updating of firmware is carried out remotely. Radio communication in the ABAX 2 system is AES encrypted.
- remotely switching on/off 230 V AC devices
- 2 control inputs
- compatible with:
- ABAX 2 system controllers (ACU-220 and ACU-280) and ARU-200 radio signal repeater
- ABAX system controllers (ACU-120, ACU-270, ACU-250 or ACU-100 (version 4.04 or higher)), INTEGRA 128-WRL system control panel and ARU-100 radio signal repeater - the required version of the device firmware should be checked in its description on the website, while ASW-210 must be in version 1.01 or higher (firmware available in ABAX 2 Firmware for ACU220 / ACU-280 from version 6.02)
- range of radio communication in the open area:
- in ABAX 2: up to 1000 m (with ACU-220 or ACU-280)
- in ABAX: up to 500 m
- remote configuration and firmware update
- compact dimensions
- in-wall mounting
The actual appearance of the products may differ from the presented images. Product descriptions are provided in the web service for information purposes only.
Documentation
Software
Certificates
Technical Data
Operating temperature range
-10°C...+55°C
Weight
40 g
Maximum humidity
93±3%
Operating frequency band
868,0 ÷ 868,6 MHz
Environmental class according to EN50130-5
II
Complied with standards
EN 50130-4, EN 50130-5
Maximum power consumption
1 W
Radio communication range (in open area) for ACU-220
up to 1000 m
Radio communication range (in open area) for ACU-280
up to 1000 m
Wetting current
10 mA
Contact rating
5 A
Maximum switching power, AC1
1250 VA
Radio communication range (in open area) for ABAX
up to 500 m
Rated contact voltage
250 V AC
Load capacity of relay outputs in AC1 category
5 A / 250 V AC
Minimum switching power
50 mW
Electrical endurance (number of switching cycles), AC1 (360 cycles/h)
>°10⁵
Contacts resistance
≤ 100 mΩ