Dual-tech PIR+MW motion detector with IR anti-masking function
SLIM-DUAL-PRO detects motion in the protected area.
- certificate of compliance with the EN 50131 requirements for Grade 3
- motion detection using two sensors: a passive infrared (PIR) sensor and a microwave (MW) sensor
- adjustable detection sensitivity of both sensors
- option to test the sensors separately
- digital motion detection algorithm
- digital temperature compensation
- digital filter of signals received by the microwave sensor to ensure immunity to false alarms caused by the power network and discharge lamps
- operating mode selection: basic or advanced
- option to enable/disable the creep zone protection
- wide-angle lens, designed specifically for SLIM LINE detectors
- option to replace the wide-angle lens with a curtain (CT-CL) or long-range (LR-CL) one
- active IR anti-masking, compliant with EN 50131-2-4 for Grade 3
- ability to configure detector operating parameters using the OPT-1 keyfob
- built-in end-of-line resistors (2EOL: 2 x 1,1 kΩ / 2 x 4,7 kΩ / 2 x 5,6 kΩ)
- LED indicator
- selectable color of LED indicator (7 colors available)
- LED indicator remote enable/disable
- configuration mode remote enable/disable
- supervision of motion detection and supply voltage circuit
- tamper protection against opening of enclosure and removal from mounting
- adjustable mounting holder (BRACKET D) included, provided with tamper switch


The actual appearance of the products may differ from the presented images. Product descriptions are provided in the web service for information purposes only.
quick installer guide
updated: 2020-06-05
443 KB
general information manual
updated: 2020-05-12
770 KB
EN-50131 GRADE 3 - certificate
updated: 2023-02-14
1.80 MB
EU declaration of conformity
updated: 2024-07-16
115 KB
Detected target velocity
0,2...3 m/s
Operating temperature range
-10°C...+55°C
Recommended mounting height
2,4 m
Max. current consumption
85 mA
Dimensions
62 x 137 x 42 mm
Environmental class according to EN50130-5
II
Complied with standards
EN 50131-1, EN 50131-2-4, EN 50130-4, EN 50130-5
Microwave frequency
24,125 GHz
Security grade according to EN50131-2-4
Grade 3
EOL resistors
2 x 1.1 kΩ / 2 x 4.7 kΩ / 2 x 5.6 kΩ
Detection area
20 m x 24 m, 90°
Alarm outputs (NC relay, resistive load)
40 mA / 24 V DC
Tamper outputs (NC relay, resistive load)
40 mA / 24 V DC
Anti-masking outputs (NC relay, resistive load)
40 mA / 24 V DC
Relay contact resistance (alarm output)
26 Ω
Permissible installation height
up to 4 m
Relay contact resistance (tamper output)
26 Ω
Relay contact resistance (anti-masking output)
26 Ω
1catalogue
3leaflet - installer
4technical data
5product data sheet